ANALISIS KUALITAS AIR UNTUK KONSENTRASI FLUORIDE PADA SISTEM JARINGAN DISTRIBUSI AIR MINUM DENGAN FLUORIDASI
DOI:
https://doi.org/10.31848/ensains.v2i1.149Abstract
Abstract:. The requirement of consumed drinking water so that it does not create disturbance to public health is that it needs a quality monitoring. Water fluoridation in Tembagapura City aims to reach its concentration level toward certain safe level, and it can provide maximum benefits for dental health. Analysis and simulation methods using EPAnet software. The results of hydrolic simulation and water quality for fluoride concentration of each node and link in the drinking water distribution network system have changed in every time change following the drinking water distribution segment. From hydraulic simulations, especially for head and flow at separate points, it consists of simultaneous solution in flow equivalence for every junction and headloss relationship in every link of network as a result of hydraulic balancing. New segment will be made at the end of each link that receives inflow from a node if the quality of the new node is different from the link in the last segment. Every pipe in network contains singular segment where the water quality is in line with the preliminary quality stated in the preliminary node. With the availability of hydraulic model and water quality for fluoride concentration, a further research can be conducted for chlorine decay, growth of by product i.e. Trihalomethans (THMs) as well as water age simultaneously in drinking water supply systems in Tembagapura City. Â
Keyword: EPAnet, distribution network, fluoride concentration.
Â
Abstrak: Persyaratan kualitas air minum yang dikonsumsi masyarakat agar tidak menimbulkan gangguan kesehatan, maka penyelenggara air minum perlu melakukan pemantauan kualitasnya. Fluoridasi air di Kota Tembagapura ditujukan untuk mencapai tingkat konsentrasi fluoride pada level tertentu yang aman dan dapat memberikan manfaat maksimal bagi kesehatan gigi. Metode analisis dan simulasi menggunakan perangkat lunak EPAnet. Hasil simulasi hidrolis dan kualitas air untuk konsentrasi fluoride pada setiap node dan link pada sistem jaringan distribusi air minum berubah pada setiap perubahan waktu mengikuti segmen distribusi air minum tersebut. Dari simulasi hidrolis, khusus untuk head dan aliran pada titik yang terpisah meliputi penyelesaian secara simultan dalam persamaan aliran untuk tiap sambungan (junction), dan hubungan headloss pada setiap link pada jaringan sebagai akibat dari hydrolic balancing. Segmen baru terbentuk pada akhir dari setiap link yang menerima inflow dari sebuah node, jika kualitas node baru berbeda dari link pada segmen terakhir. Setiap pipa dalam jaringan mengandung segmen tunggal, di mana kualitas air sebanding dengan kualitas awal yang ditetapkan di node awal. Dengan tersedianya model hidrolis dan kualitas air untuk konsentrasi fluoride, maka dapat dilakukan penelitian lanjutan untuk peluruhan klorin, pertumbuhan by product yaitu trihalomethans (THMs) serta usia air secara simultan pada sistem penyediaan air minum di Kota Tembagapura.
Kata Kunci: EPAnet, jaringan distribusi, konsentrasi fluoride.
References
Gleick, P. H. (1996). Basic Water Requirements for Human Activities: Meeting Basic Needs, Water International, 21:2, 83-92, DOI: 10.1080/02508069608686494
Pucher, J. & Dijkstra, L. (2003). Promoting Safe Walking and Cycling to Improve Public Health: Lessons from the Netherlands and Germany, American Journal of Public Health, 93:9, 1509-1516. DOI: 10.2105/AJPH.93.9.1509
Peraturan Menteri Kesehatan Republik Indonesia Nomor 492/MENKES/PER/IV/2010 tentang Persyaratan Kualitas Air Minum. 2010. Jakarta.
Peraturan Pemerintah Republik Indonesia Nomor 16 Tahun 2005 tentang Pengembangan Sistem Penyediaan Air Minum. 2005. Jakarta.
Peraturan Menteri Pekerjaan Umum Nomor: 18/PRT/M/2007 tentang Penyelenggaraan Pengembangan Sistem Penyediaan Air Minum. 2007. Jakarta.
Ayoob, S. & Gupta, A. K. (2006). Fluoride in Drinking Water: A Review on the Status and Stress Effects, Critical Reviews in Environmental Science and Technology, 36:6, 433-487, DOI: 10.1080/10643380600678112
Fawell, J., Bailey, K., Chilton, J., Dahi, E., Fewtrell, L., Magara Y. (2006). Fluoride in Drinking-water. World Health Organization (WHO).
WHO. (2011). Guidelines for drinking-water quality, 4th Ed. Geneva.
Rossman, L. A. (2000). EPANET 2 User Manual. Water Supply and Water Resources Divison, National Risk Management Research Laboratory, Cincinati, OH. United Nation Environmental Protection Agency.
Reeves, T. G. (1991). Water Fluoridation A Manual for Engineers and Technicians. U.S. Department of Health and Human Services: Public Health Services. Center For Disease Control. Atlanta, Georgia.
Newbrun, E. (1989). Effectiveness of Water Fluoridation, Journal of Public Health Dentistry, 49:5, 279-289, https://doi.org/10.1111/j.1752-7325.1989.tb02086.x
Sintawati, F. X. (2003). Studi Evaluasi Akhir Fluoridasi Air Minum di Kodya Banjarmasin. Badan Penelitian Kesehatan.
American Society for Testing and Materials. ASTM Designation: D 1179-04. Standard Methods for Fluoride Ion in Water1. Annual Book of ASTM Standards 2006. Section 11.01 Water (I) Water and Environmental Technology. ASTM International: West Conshohocken, PA, USA.
American Society for Testing and Materials. ASTM Designation: D 3370-95a. Sampling Water from Closed Conduits1. Annual Book of ASTM Standards 2006. Section 11.01 Water (I) Water and Environmental Technology. ASTM International: West Conshohocken, PA, USA.
American Society for Testing and Materials. ASTM Designation: D 1192-98. Equipment for Sampling Water and Steam in Closed Conduits. Annual Book of ASTM Standards 2006. Section 11.01 Water (I) Water and Environmental Technology. ASTM International: West Conshohocken, PA, USA.
American Society for Testing and Materials. ASTM Designation: D 5463-03. Use of Test Kits to Measure Inorganic Constituent in Water1. Annual Book of ASTM Standards 2006. Section 11.01 Water (I) Water and Environmental Technology. ASTM International: West Conshohocken, PA, USA.
Yang, Y. J., Goodrich, J. A., Clark, R. M., Li, S. Y. (2008). Modeling and Testing of Reactive Contaminant Transport in Drinking Water Pipes: Chlorine Response and Implications for Online Contaminant Detection, Water Research, 42, 1397-1412. DOI:10.1016/j.watres.2007.10.009